Eptifibatide Impurity 2
Need Assistance?
  • US & Canada:
    +
  • UK: +

Eptifibatide Impurity 2

* Please kindly note that our products are not to be used for therapeutic purposes and cannot be sold to patients.

Eptifibatide Impurity 2 is an impurity of Eptifibatide, which is an antiplatelet drug of glycoprotein IIb/IIIa inhibitor.

Category
Others
Catalog number
BAT-009057
Molecular Formula
C35H51N11O10S2
Molecular Weight
849.98
Sequence
Trp-Pro-Cys(1)-NH2, Cys(1)-deamino-hArg-Gly-Asp(Disulfide bond)
1. Compatibility of argatroban with abciximab, eptifibatide, or tirofiban during simulated Y-site administration
Kamlesh Patel, Marcie J Hursting Am J Health Syst Pharm. 2005 Jul 1;62(13):1381-4. doi: 10.2146/ajhp040391.
Purpose: The physical and chemical compatibility of argatroban with abciximab, eptifibatide, or tirofiban during simulated Y-site administration was studied. Methods: Test solutions of argatroban 1 mg/mL, abciximab 36 microg/mL, eptifibatide 2 mg/mL, and tirofiban 50 microg (as the hydrochloride salt) per milliliter in 5% dextrose injection (D5W) and in 0.9% sodium chloride injection (saline) were prepared in duplicate by using aseptic technique. Argatroban solution was mixed with abciximab, eptifibatide, or tirofiban solution, each at a ratio of 1:1 by volume, and at 4:1 with abciximab solution, 8:1 with tirofiban solution, and 16:1 with eptifibatide solution. Compatibility was evaluated immediately after solution preparation and after storage for four hours at 20-25 degrees C. Physical compatibility was determined with the unaided eye and with a particle counter, and chemical compatibility was measured with high-performance liquid chromatography. The chemical compatibility of argatroban and abciximab was not tested because of the poor stability or recovery of abciximab in the test diluents. Results: Argatroban was physically compatible with abciximab, eptifibatide, and tirofiban in D5W at each ratio tested and in saline at a 1:1 ratio. Argatroban was chemically compatible with eptifibatide and tirofiban. No significant impurities were detected, except for a single impurity in argatroban-eptifibatide 1:1 admixtures. Conclusion: At concentrations commonly used in practice, argatroban was physically compatible with abciximab and physically and chemically compatible with eptifibatide and tirofiban for four hours at 20-25 degrees C.
2. Characterization of eptifibatide during drug formulation stability assays
Ronghua Wang, Debby Feder, Frank Hsieh J Pharm Biomed Anal. 2003 Dec 4;33(5):1181-7. doi: 10.1016/s0731-7085(03)00409-6.
The objective of the study was to determine the identity of a new impurity detected in HPLC chromatograms of research samples of eptifibatide manufactured by a new process and formulated into drug product. The identification of the unknown impurity was required in order to understand the mechanism of its formation. The analysis was performed by using tandem mass spectrometers coupled with a reversed-phase gradient HPLC system. The unknown compound was then structurally elucidated by matrix-assisted laser desorption ionization (MALDI) tandem mass spectrometry. The mass spectrometric results showed that the protonated molecular ion of the unknown compound was m/z 862.3347 with molecular formula: C(36)H(52)N(11)O(10)S(2). The unknown compound was a linear peptide and was related to Asp-clipped eptifibatide. It was formed from Asp-clipped eptifibatide by the reaction of the amino group of tryptophan moiety with formaldehyde followed by electrophilic attack on the nitrogen of indole.
Online Inquiry
Verification code
Inquiry Basket