1.Pharmaceutical treatments to prevent recurrence of endometriosis following surgery: a model-based economic evaluation.
Sanghera S1, Barton P2, Bhattacharya S3, Horne AW4, Roberts TE2; PRE-EMPT research group. BMJ Open. 2016 Apr 15;6(4):e010580. doi: 10.1136/bmjopen-2015-010580.
OBJECTIVE: Conduct an economic evaluation based on best currently available evidence comparing alternative treatments levonorgestrel-releasing intrauterine system, depot-medroxyprogesterone acetate, combined oral contraceptive pill (COCP) and 'no treatment' to prevent recurrence of endometriosis after conservative surgery in primary care, and to inform the design of a planned trial-based economic evaluation.
2.Development of a microfluidic paper-based analytical device for the determination of salivary aldehydes.
Ramdzan AN1, Almeida MI1, McCullough MJ2, Kolev SD3. Anal Chim Acta. 2016 May 5;919:47-54. doi: 10.1016/j.aca.2016.03.030. Epub 2016 Mar 19.
A low cost, disposable and easy to use microfluidic paper-based analytical device (μPAD) was developed for simple and non-invasive determination of total aldehydes in saliva with a potential to be used in epidemiological studies to assess oral cancer risk. The μPAD is based on the colour reaction between aldehydes (e.g. acetaldehyde, formaldehyde), 3-methyl-2-benzothiazolinone hydrazone (MBTH) and iron(III) to form an intense blue coloured formazan dye. The newly developed μPAD has a 3D design with two overlapping paper layers. The first layer comprises 15 circular detection zones (8 mm in diameter), each impregnated with 8 μL of MBTH, while the second layer contains 15 reagent zones (4 mm in diameter). Two μL of iron(III) chloride are added to each one of the second layer zones after the addition of sample to the detection zones in the first layer. All hydrophilic zones of the μPAD are defined by wax printing using a commercial wax printer.
3.Silica-based polypeptide-monolithic stationary phase for hydrophilic chromatography and chiral separation.
Zhao L1, Yang L2, Wang Q3. J Chromatogr A. 2016 Apr 7. pii: S0021-9673(16)30419-8. doi: 10.1016/j.chroma.2016.04.014. [Epub ahead of print]
Glutathione (GSH)-, somatostatin acetate (ST)- and ovomucoid (OV)-functionalized silica-monolithic stationary phases were designed and synthesized for HILIC and chiral separation using capillary electrochromatography (CEC). GSH, ST and OV were covalently incorporated into the silica skeleton via the epoxy ring-opening reaction between their amino groups and the glycidyl moiety in γ-glycidoxypropyltrimethoxysilane (GPTMS) together with polycondensation and copolymerization of tetramethyloxysilane and GPTMS. Not only could the direction and electroosmotic flow magnitude on the prepared GSH-, ST- and OV-silica hybrid monolithic stationary phases be controlled by the pH of the mobile phase, but also a typical HILIC behavior was observed so that the nucleotides and HPLC peptide standard mixture could be baseline separated using an aqueous mobile phase without any acetonitrile during CEC. Moreover, the prepared monolithic columns had a chiral separation ability to separate dl-amino acids.
4.Highly sensitive LC-MS/MS-ESI method for determination of phenelzine in human plasma and its application to a human pharmacokinetic study.
Kallem RR1, Jillela B2, Ravula AR3, Samala R4, Andy A5, Ramesh M6, Rao JS7. J Chromatogr B Analyt Technol Biomed Life Sci. 2016 Apr 9;1022:126-132. doi: 10.1016/j.jchromb.2016.04.006. [Epub ahead of print]
A selective, sensitive and rapid LC-MS/MS method has been developed and validated for quantification of the phenelzine (PZ) in 200μL of human plasma using hydroxyzine (HZ) as an internal standard (IS) as per regulatory guidelines. The sample preparation involved the derivatization of PZ using pentaflurobenzaldehyde followed by solid phase extraction process to extract PZ and HZ from human plasma. LC-MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electro spray ionization technique in positive ion mode and the transitions of m/z 305.1→105.1 and m/z 375.3→201.1 were used to measure the derivative of PZ and IS, respectively. The total run time was 3.5min and the elution of PZ and HZ occurred at 2.53, and 1.92min, respectively; this was achieved with a mobile phase consisting of 10mM ammonium acetate: acetonitrile (20:80, v/v) at a flow rate of 1.0mL/min on an Ace C18 column with a split ratio of 70:30. The developed method was validated in human plasma with a lower limit of quantitation 0.